SCHNEIDER ACTI 9 CIRCUIT BREAKER K60H 2P 32A B CURVE 10000A 400V [6PCS/INNER]

INVENTORY CODE:
       
BRAND: SCHNEIDER ELECTRIC SINGAPORE
(OUT OF STOCK: SG 0 PIECE)
Size
Color
Piece:

Miniature circuit breaker (MCB), Acti9 K60H, 2P, 32A, B curve, 10000A (IEC/EN 60898-1)

This Acti9 K60H product is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles and 32A In rated current and B tripping curve. The rated short circuit breaking capacity goes up to 10000A at 400VAC conforming to EN/IEC 60898-1 standard and at conforming to standard. This product is compliant with EN/IEC 60898-1 standard. This miniature circuit breaker combines functions of circuit protection against short circuit and overload current, control and isolation. The connection can be made downstream by biconnect comb busbar. It can be also made upstream/downstream by tunnel terminals. A padlock device is available for work to be carried out on live parts. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The operating frequency is 50Hz or 60Hz. It can be mounted on DIN rail for modular installation. Its width is 4 pitches of 9mm. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 81mm x (D) 70mm. The weight is 0.24kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -25°C to 70°C. The storage temperature is -25°C to 85°C.

Specifications

Main
Device application Distribution
Range Acti9
Product name Acti9 K60
Product or component type Miniature circuit-breaker
Device short name K60H
Poles description 2P
Number of protected poles 2
[In] rated current 32 A
Network type AC
Trip unit technology Thermal-magnetic
Curve code B
breaking capacity 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
utilisation category Category A conforming to IEC 60947-2
suitability for isolation Yes conforming to EN/IEC 60898-1
Standards EN/IEC 60898-1
Product certifications VDE
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 3...5 x In
[Ics] rated service breaking capacity 10000 A 75 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz
limitation class 3 conforming to EN/IEC 60898-1
[Ui] rated insulation voltage 440 V AC 50/60 Hz conforming to EN/IEC 60898-1
[Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60898-1
Contact position indicator No
Control type Toggle
Local signalling Without
Mounting mode Fixed
Mounting support DIN rail
comb busbar and distribution block compatibility Downside: biconnect
9 mm pitches 4
Height 81 mm
Width 36 mm
Depth 70 mm
Net weight 0.24 kg
colour White
Mechanical durability 20000 cycles
electrical durability 10000 cycles
connections - terminals Tunnel type terminals (downstream) 0.5…35 mm² rigid
wire stripping length 14 mm for top or bottom connection
tightening torque 3.5 N.m top or bottom
Earth-leakage protection Without
Environment
IP degree of protection IP20 conforming to IEC 60529
pollution degree 2 conforming to IEC 60898-1
Overvoltage category II
tropicalisation 2 conforming to IEC 60068-1
relative humidity 95 % at 55 °C
Operating altitude 0...2000 m
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -25…85 °C