Detcon Dm-700-Hbr Hydrogen Bromide Sensor Assembly
INVENTORY CODE:
BRAND: DETCON
Detcon Dm-700-Hbr Hydrogen Bromide Sensor Assembly
Part# with Options:
Detcon Model 700 Series Sensors are a non-intrusive “Smart” sensors designed to detect and monitor oxygen and Toxic Gases in air using electrochemical sensor technology. The intelligent plug-in, field replaceable cell provides automatic recognition of gas type and range, and features over-sized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an intrinsically safe electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model 700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model 700 is equipped with standard analog 4-20mA, and ModbusTM RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM), HART, and Foundation Fieldbus. Detcon’s toxic gas and oxygen sensors have a long shelf life and are supported by an industry-leading warranty.
Features Failsafe User-Friendly Interface
- LED Display (With Antiglare Cover)
- Full Text Display Method
- Non-intrusive Interface
- Auto Zero/Auto Span
- Pre-emptive Fault Diagnostics
Environmentally Bulletproof
- Electropolished 316SS Construction
- 100% Epoxy Encapsulated Circuitry
- Bulletproof I/O Protection
- Water-Proof, Corrosion-Proof, Vibration-Proof
Modular and Serviceable
- Modular Design
- Plug and Play Components
- Quick Thread Release (For Sensor Replacement)
- Integral Calibration Port
Applications
- Oil & Gas
- Chemical Plants
- Food and Beverage
- Steel Mills
- Pulp and Paper
- Refineries
- Wastewater Treatment Plants
- Utilities
967-090890-030
Specifications
Sensor Type | Continuous diffusion/adsorption 3-electrode electrochemical cell Plug-in field replaceable Type |
Measurement Range | 0-30 ppm |
Accuracy/Repeatability | ±2% FS |
Response/Clearing Time | T90≤70 seconds |
Outputs | Linear 4-20 mA DC RS-485 MODBUS-RTU |
Electrical Classification | Explosion proof CSA and US (NRTL) Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C) Class I, Zone 1, Group IIC ATEX II 2 G Ex d ib IIB + H2 T4 GB |
Ingress Protection | NEMA 4X, IP66 |
Safety Approvals | CCSAUS ATEX CE Marking SIL2 Certified to IEC 61508 |
Environmental Specifications | |
Operating Temperature Range | -4 to 104oF/-20 to 40oC |
Storage Temperature Range | -31 to 131oF/-35 to 55oC |
Operating Humidity Range | 10-95% RH non-condensing |
Mechanical Specifications | |
Dimensions | 7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only) 11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box) Mechanical Connection: Mounting holes (J-box) 5.5"; 140mm center to center |
Weight | 2 lbs; 0.907kg (sensor only) 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) |
Electrical Specifications | |
Power Input | 11-30 VDC |
Power Consumption | Normal operation = 30mA @24V (<0.75 watt) Maximum = 50mA @24V (1.2 watts) |
Inrush Current | 500mA @ 24V (typical) |
RFI/EMI Protection | Complies with EN50270 |
Analog Output | Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA: All Fault Diagnostics 2mA: In-Calibration 4-20mA: 0-100% full-scale 22mA: Over-range condition |
Serial RS-485 Output | RS-485 ModbusTM RTU |
Baud Rate (optional) | 9600 BPS (9600,N,8,1 Half Duplex) |
Status Indicators | 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan Set-up Options, and Fault Reporting |
Faults Monitored | Loop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration |
Cable Requirements | Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG Serial Output 2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations Maximum distance is 4,000 feet to last sensor |
I/O Protection | Over-voltage, Miswiring, EMI/RFI Immunity |
Export Info | |
Made in | United States |
Harmonized Tariff Code (HTC) | 9027102000 |