Air Systems Carbon Monoxide Airline Monitor, Replacement For Monitor In Breather Box

INVENTORY CODE:
       
BRAND: AIR SYSTEMS INC.

Watch Video

(OUT OF STOCK: SG 0 PIECE)
Size
Color
Piece:

Air Systems Carbon Monoxide Airline Monitor Replacement For Monitor In Breather-Box® CO-91

  • Calibration time: Less than 2 minutes
  • Monitor display: LCD 3-digit readout
  • Temperature range: 4°F to 113°F (-20°C to 45°C)
  • Accuracy: +/- 1% of full scale
  • Monitor range: Carbon Monoxide (CO) 0-200 ppm, Oxygen (O2) optional 15-23%
  • Pressure range: 1-3 psi, flow 50-100 cc
  • Response: 90% of full scale in 10 seconds
  • Sensor type: 3-electrode electrochemical with bias voltage
  • Humidity range: 5% to 95% relative humidity
  • Warranty: 2 years on entire unit and CO sensor (1 year on O2 sensor)
  • Alarm set point: 10 ppm CO (5 ppm Canada); 19.5% O2 option
  • Voltage operation: 115VAC, dual 9 VDC battery, or 8-16VDC, 230VAC optional
  • Shielding: Internal RFI/EMI circuitry, aluminum case
  • Test circuitry: Manual push-to-test for sensor operation and alarms
  • Warning indicators: Low battery (amber), normal operation (green), high CO (red), low O2 option (red). LED locations may vary with model ordered.
  • Output signals (standard): DC output on portables, AC output on panel versions
  • Monitor housing: Black anodized aluminum
  • Control panel standard features: Inlet gas quick connect coupling, auxiliary 12VDC jack, on/off/test switch, auxiliary/remote alarm jack, 115VAC jack
  • CO or CO/O2 monitors available with intrinsically safe (IS) certification

About AIR SYSTEMS INC. 

AIR SYSTEMS INC. has the most comprehensive range of breathing air filtration & compressor systems for confined space. It includes HEPA vacuums, ventilation systems and fume extractor.

  • Nominal Range - 0-1000 ppm
  • Maximum Overload - 2000 ppm
  • Expected Operating Life - 24 months in air
  • Resolution - 0.5 ppm
  • Response Time (90%) - < 30 seconds
  • Pressure Range - Atmosphere +/- 10%
  • Typical Baseline Range (pure air) - -2 to 3 ppm equivalent
  • Maximum Zero Shift - 9 ppm equivalent
  • Long Term Output Drift - < 5% singal loss per month
  • Humidity Range - 15-90%RH, non-condensing
  • Recommended Load - 10 ohms
  • Bias Voltage - None Required
  • Output Linearity - Linear
  • Position Sensitivity - None
  • Storage Life - 6 months in container
  • Storage Temperature - 0 to 20 degrees C
  • Warranty - 24 Months